Elsema Penta 5 Ch Receiver 12-24V PCR43305R

Brand: Elsema

Elsema Logo

Elsema Penta 5 Ch Receiver 12-24V PCR43305R

Brand: Elsema

Elsema Logo

Includes:

  • Genuine Elsema Wire-In 5 Channel Receiver
  • Micro Antenna
  • Programming Instructions
  • Free Shipping Australia-Wide*
  • 2 Years Manufacturers Warranty*

$119.95

Availability:

Only 2 left in stock

Availability:

In stock

Includes:

  • Genuine Elsema Wire-In 5 Channel Receiver
  • Micro Antenna
  • Programming Instructions
  • Free Shipping Australia-Wide*
  • 2 Years Manufacturers Warranty*

Includes:

  • Genuine Elsema Wire-In 5 Channel Receiver
  • Micro Antenna
  • Programming Instructions
  • Free Shipping Australia-Wide*
  • 2 Years Manufacturers Warranty*

Please note: Although this item is marked as in stock, our Elsema stock is consistently replenished to meet demand. Due to frequent bulk orders, stock levels can be challenging to determine in real-time. If you need an estimated time of arrival (ETA), please feel free to contact us, and we’ll be happy to assist!

Features:

  • 5-channel receiver with relay output
  • Frequency hopping (433.10 to 434.70MHz) for secure communication
  • Dual coding options: 12-way dip switch or encrypted codes
  • Unlimited remote pairing with PentaFOB® and PentaCODE® remotes
  • User-selectable output modes: momentary, latching, and security latching
  • Antenna diversity for robust and extended range operation
  • Wide operating voltage range (12-24V AC/DC) and low power consumption
  • On-board diagnostic LEDs for power, reception, and relay activation

Applications for use:

  • Keyless access control for gates and doors
  • Home automation for lights, garden systems, and swimming pools
  • Security system activation and lighting control
  • Industrial machinery control in warehouses or factories
  • Automotive and equipment automation

The Elsema PCR43305R 5-Channel Penta Receiver is a high-performance, versatile solution for wireless control applications, operating on the 433MHz frequency with frequency hopping technology to ensure secure and interference-free communication. Designed for seamless integration into automatic gate openers, garage doors, lighting systems, and more, this receiver offers flexible control with its five relay outputs. Each relay can be programmed in momentary, latching, or security latching modes, providing adaptability for a wide range of applications.

The receiver is compatible with Elsema’s PentaFOB® and PentaCODE® remotes, allowing for unlimited remote pairing. Installers can choose between the classic 12-way dip switch coding system or encrypted coding with over 17 billion possible code combinations, ensuring a secure and customizable installation. Antenna diversity technology further enhances the range and reliability of the connection, making this receiver suitable for both short and long-range operations. The Elsema PCR43305R is equipped with on-board diagnostic LEDs for power, reception, and relay activation, simplifying the setup and troubleshooting process.

With wide supply voltage support (12-24V AC/DC) and low power consumption, this receiver is perfect for industrial, residential, and commercial use cases, from keyless access control and home automation to machinery control in factories.

Frequently Asked Questions

How many remotes can I program to the Elsema PCR43305R?
The Elsema PCR43305R receiver supports unlimited remote pairing, making it ideal for multi-user environments such as gated communities, commercial buildings, or industrial facilities.

What coding options are available for this receiver?
The PCR43305R offers dual coding options: 12-way dip switch coding for easy matching of remotes and encrypted coding with over 17 billion combinations for enhanced security.

Can I switch between momentary and latching modes?
Yes, the PCR43305R supports user-selectable output modes, including momentary, latching, and security latching. These modes can be easily changed using the 6-way dip switch settings.

What applications is the Elsema PCR43305R best suited for?
This 5-channel receiver is versatile and can be used for automatic gates, garage doors, lighting control, security systems, and even industrial machinery control in factories and warehouses.

Does this receiver support long-range applications?
Yes, the PCR43305R features antenna diversity, which allows for enhanced signal strength and extended range. For long-range applications, an ANT433 series antenna is recommended.

Weight.20 kg
Channels

5 Channel

MPN

Does Not Apply

UPC

Does not apply

Application

, , ,

AS62368.1 Battery Compliant

Not Applicable

Brand

Elsema

Type

Features

Easy Installation, Genuine, Multiple Frequency Hopper

Frequency

433.92 MHz

Voltage

12-24V

Warranty

2 Years*

Supply Voltage12 – 24 Volts AC or DC. Can use Elsema’s AC power pack (12PP-1000)
Standby Current15 mA stand by at 24VDC
Current Consumption91 mA with all relays “On”
Frequency Band433.100 to 434.700MHz
Operating Temperature Range-5 to 50°C
Receiver Memory StorageUnlimited Remotes
Decoding SystemEncrypted 17 billion codes combinations or On board 12-way code switch
Outputs5 change over relay outputs, rated at 10 Amps 240VAC each
Relay ContactsCommon (C) , Normally Closed (NC) & Normally Open (NO)
ConnectionsSupply and Antenna is a screw type terminal block
Relay outputs are plug-in type terminal block
AntennaANT433 series for long range applications. Antenna wire for short range applications
Operating RangeRefer to the remote control or transmitter datasheet
Dimensions130 x 70 x 27
Useable TransmittersFOB433 series and PCK series

 

PCR43305R

Programming Instructions for PentaFOB® and PentaCODE® Remotes with the Elsema PCR43305R Receiver

PentaFOB® Remote Programming

Method 1: Remote to Receiver

  1. Ensure that all switches on the receiver’s 12-way dip switch are set to “OFF.”
  2. Press and hold the program button on the receiver.
  3. Press the button on the PentaFOB® remote for 2 seconds.
    • The receiver’s LED will flash and then turn green.
  4. Release the button on the receiver and the remote.
  5. Test the remote by pressing its button to ensure the receiver responds.

Method 2: Remote to Remote (Near Receiver)

  1. Open the case of an already programmed remote.
  2. Press and release the program button on the back of the board (receiver enters learning mode).
  3. Press the button on the already programmed remote to activate the receiver.
  4. Press the button on the new remote you want to program for 2 seconds.
  5. Press the program button again on the already programmed remote to exit learning mode.
  6. Test the newly programmed remote to confirm it works.

Deleting Receivers Memory for PentaFOB® Remotes

  • Delete All Remotes: Short the Code Reset pins on the receiver for 10 seconds. This will erase all the remotes stored in the receiver’s memory.

PentaCODE® Remote Programming

Method 1: 12-Way Dip Switch Coding

  1. Set a unique code on the receiver’s 12-way dip switch by flipping the switches “On” or “Off” (do not use the factory default setting).
  2. Open the battery cover of the PentaCODE® remote.
  3. Match the 12-way dip switch on the remote to the code set on the receiver’s dip switch.
  4. Press button 1 on the remote. The receiver output should activate, confirmed by the receiver’s LED.
  • Programming Buttons 2, 3, or 4 to Other Receivers: To use buttons 2, 3, or 4 with other receivers, adjust dip switches 11 and 12 on the respective receivers as follows:
    ReceiverDip Switch 11Dip Switch 12
    1OffOff
    2OnOff
    3OffOn
    4OnOn
  • Ensure that dip switches 1 to 10 are the same on both the remotes and receivers.

Method 2: Encrypted Coding (All 12-Way Dip Switches “Off”)

  1. Press and hold the program button on the receiver.
  2. Press the button you want to program on the PentaCODE® remote for 2 seconds.
    • The receiver’s LED will flash green.
  3. Release the button on the receiver and the remote.
  4. The LED on the PentaCODE® remote will flash to confirm successful coding.

Method 3: Remote to Remote / Remote to Receiver Broadcasting

  • Broadcasting the Remote’s Code:
    1. Ensure all 12 dip switches on the remote are “Off.”
    2. Press and hold button 1, then toggle dip switch 12 “On” and then back to “Off.”
    3. The LED will stay on for 10 seconds, indicating the remote is broadcasting its code.

 

  • Broadcasting the Receiver’s Code:
    1. Ensure all 12 dip switches on the receiver are “Off.”
    2. Toggle dip switch 12 “On” and then back to “Off.”
    3. The green LED will remain on for 10 seconds, indicating the receiver is broadcasting its code.

 

  • Programming the New Remote:
    1. While broadcasting, press button 1 on the new remote for 1 second.
    2. Release the button. The LED will flash twice to confirm successful programming.

Broadcasting will remain active for 10 seconds or stop if any dip switch is turned on.

Deleting Receivers Memory for PentaCODE® Remotes

  • Delete All Remotes: Short the CC pin on the receiver for 10 seconds. This will erase all remotes stored in the receiver’s memory.

Programming Instructions for Elsema PCR43305R

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Includes:

  • Genuine Elsema Wire-In 5 Channel Receiver
  • Micro Antenna
  • Programming Instructions
  • Free Shipping Australia-Wide*
  • 2 Years Manufacturers Warranty*

Please note: Although this item is marked as in stock, our Elsema stock is consistently replenished to meet demand. Due to frequent bulk orders, stock levels can be challenging to determine in real-time. If you need an estimated time of arrival (ETA), please feel free to contact us, and we’ll be happy to assist!

Features:

  • 5-channel receiver with relay output
  • Frequency hopping (433.10 to 434.70MHz) for secure communication
  • Dual coding options: 12-way dip switch or encrypted codes
  • Unlimited remote pairing with PentaFOB® and PentaCODE® remotes
  • User-selectable output modes: momentary, latching, and security latching
  • Antenna diversity for robust and extended range operation
  • Wide operating voltage range (12-24V AC/DC) and low power consumption
  • On-board diagnostic LEDs for power, reception, and relay activation

Applications for use:

  • Keyless access control for gates and doors
  • Home automation for lights, garden systems, and swimming pools
  • Security system activation and lighting control
  • Industrial machinery control in warehouses or factories
  • Automotive and equipment automation

The Elsema PCR43305R 5-Channel Penta Receiver is a high-performance, versatile solution for wireless control applications, operating on the 433MHz frequency with frequency hopping technology to ensure secure and interference-free communication. Designed for seamless integration into automatic gate openers, garage doors, lighting systems, and more, this receiver offers flexible control with its five relay outputs. Each relay can be programmed in momentary, latching, or security latching modes, providing adaptability for a wide range of applications.

The receiver is compatible with Elsema’s PentaFOB® and PentaCODE® remotes, allowing for unlimited remote pairing. Installers can choose between the classic 12-way dip switch coding system or encrypted coding with over 17 billion possible code combinations, ensuring a secure and customizable installation. Antenna diversity technology further enhances the range and reliability of the connection, making this receiver suitable for both short and long-range operations. The Elsema PCR43305R is equipped with on-board diagnostic LEDs for power, reception, and relay activation, simplifying the setup and troubleshooting process.

With wide supply voltage support (12-24V AC/DC) and low power consumption, this receiver is perfect for industrial, residential, and commercial use cases, from keyless access control and home automation to machinery control in factories.

Frequently Asked Questions

How many remotes can I program to the Elsema PCR43305R?
The Elsema PCR43305R receiver supports unlimited remote pairing, making it ideal for multi-user environments such as gated communities, commercial buildings, or industrial facilities.

What coding options are available for this receiver?
The PCR43305R offers dual coding options: 12-way dip switch coding for easy matching of remotes and encrypted coding with over 17 billion combinations for enhanced security.

Can I switch between momentary and latching modes?
Yes, the PCR43305R supports user-selectable output modes, including momentary, latching, and security latching. These modes can be easily changed using the 6-way dip switch settings.

What applications is the Elsema PCR43305R best suited for?
This 5-channel receiver is versatile and can be used for automatic gates, garage doors, lighting control, security systems, and even industrial machinery control in factories and warehouses.

Does this receiver support long-range applications?
Yes, the PCR43305R features antenna diversity, which allows for enhanced signal strength and extended range. For long-range applications, an ANT433 series antenna is recommended.

Weight.20 kg
Channels

5 Channel

MPN

Does Not Apply

UPC

Does not apply

Application

, , ,

AS62368.1 Battery Compliant

Not Applicable

Brand

Elsema

Type

Features

Easy Installation, Genuine, Multiple Frequency Hopper

Frequency

433.92 MHz

Voltage

12-24V

Warranty

2 Years*

Supply Voltage12 – 24 Volts AC or DC. Can use Elsema’s AC power pack (12PP-1000)
Standby Current15 mA stand by at 24VDC
Current Consumption91 mA with all relays “On”
Frequency Band433.100 to 434.700MHz
Operating Temperature Range-5 to 50°C
Receiver Memory StorageUnlimited Remotes
Decoding SystemEncrypted 17 billion codes combinations or On board 12-way code switch
Outputs5 change over relay outputs, rated at 10 Amps 240VAC each
Relay ContactsCommon (C) , Normally Closed (NC) & Normally Open (NO)
ConnectionsSupply and Antenna is a screw type terminal block
Relay outputs are plug-in type terminal block
AntennaANT433 series for long range applications. Antenna wire for short range applications
Operating RangeRefer to the remote control or transmitter datasheet
Dimensions130 x 70 x 27
Useable TransmittersFOB433 series and PCK series

 

PCR43305R

Programming Instructions for PentaFOB® and PentaCODE® Remotes with the Elsema PCR43305R Receiver

PentaFOB® Remote Programming

Method 1: Remote to Receiver

  1. Ensure that all switches on the receiver’s 12-way dip switch are set to “OFF.”
  2. Press and hold the program button on the receiver.
  3. Press the button on the PentaFOB® remote for 2 seconds.
    • The receiver’s LED will flash and then turn green.
  4. Release the button on the receiver and the remote.
  5. Test the remote by pressing its button to ensure the receiver responds.

Method 2: Remote to Remote (Near Receiver)

  1. Open the case of an already programmed remote.
  2. Press and release the program button on the back of the board (receiver enters learning mode).
  3. Press the button on the already programmed remote to activate the receiver.
  4. Press the button on the new remote you want to program for 2 seconds.
  5. Press the program button again on the already programmed remote to exit learning mode.
  6. Test the newly programmed remote to confirm it works.

Deleting Receivers Memory for PentaFOB® Remotes

  • Delete All Remotes: Short the Code Reset pins on the receiver for 10 seconds. This will erase all the remotes stored in the receiver’s memory.

PentaCODE® Remote Programming

Method 1: 12-Way Dip Switch Coding

  1. Set a unique code on the receiver’s 12-way dip switch by flipping the switches “On” or “Off” (do not use the factory default setting).
  2. Open the battery cover of the PentaCODE® remote.
  3. Match the 12-way dip switch on the remote to the code set on the receiver’s dip switch.
  4. Press button 1 on the remote. The receiver output should activate, confirmed by the receiver’s LED.
  • Programming Buttons 2, 3, or 4 to Other Receivers: To use buttons 2, 3, or 4 with other receivers, adjust dip switches 11 and 12 on the respective receivers as follows:
    ReceiverDip Switch 11Dip Switch 12
    1OffOff
    2OnOff
    3OffOn
    4OnOn
  • Ensure that dip switches 1 to 10 are the same on both the remotes and receivers.

Method 2: Encrypted Coding (All 12-Way Dip Switches “Off”)

  1. Press and hold the program button on the receiver.
  2. Press the button you want to program on the PentaCODE® remote for 2 seconds.
    • The receiver’s LED will flash green.
  3. Release the button on the receiver and the remote.
  4. The LED on the PentaCODE® remote will flash to confirm successful coding.

Method 3: Remote to Remote / Remote to Receiver Broadcasting

  • Broadcasting the Remote’s Code:
    1. Ensure all 12 dip switches on the remote are “Off.”
    2. Press and hold button 1, then toggle dip switch 12 “On” and then back to “Off.”
    3. The LED will stay on for 10 seconds, indicating the remote is broadcasting its code.

 

  • Broadcasting the Receiver’s Code:
    1. Ensure all 12 dip switches on the receiver are “Off.”
    2. Toggle dip switch 12 “On” and then back to “Off.”
    3. The green LED will remain on for 10 seconds, indicating the receiver is broadcasting its code.

 

  • Programming the New Remote:
    1. While broadcasting, press button 1 on the new remote for 1 second.
    2. Release the button. The LED will flash twice to confirm successful programming.

Broadcasting will remain active for 10 seconds or stop if any dip switch is turned on.

Deleting Receivers Memory for PentaCODE® Remotes

  • Delete All Remotes: Short the CC pin on the receiver for 10 seconds. This will erase all remotes stored in the receiver’s memory.

Programming Instructions for Elsema PCR43305R

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.