Features:

  • 1 x Genuine ATA CB6 Control Board
  • Controls up to 2 AC motors (either single or three phase – via contactors) with microprocessor logic
  • 2 Years Manufacturer’s Warranty*
  • Free Standard Shipping Australia-Wide*

Includes:

  • 1 x ATA CB6 Control Board
  • Weather resistant control box
  • 240V transformer
  • Installation Instructions

Note:  Receiver or transmitters or inverter are NOT included in this product.

Compatibility List:

The CB6 Control Board is compatible with ATA Industrial Gate and Shutters.

Control up to two AC motors (either single or three phase – via contactors) with microprocessor logic. The CB6 Control Board offers true flexibility with a variety of input triggers including Safety Beam, swipe card, loop detector, etc.

 

Weight.5 kg
Application

, ,

Brand

ATA

Type

 MinimumMaximum
Supply Voltage240 VAC Supply450V peak
24 VAC Supply29VAC
Input VoltagesControl and Safety Inputs-50 Volts100 Volts
Limit Switch Inputs-50 Volts100 Volts
OutputsLock Output (switching voltage)30 VAC / DC
Lock Output (switching current [inductive])3 AMPS
Light Output Module (switching voltage)240 VAC / 30 VDC
Light Output Module (switching current)10A AC / DC
Total Motor Output Current5 AMP (5 AMP fuse protected)

 

NOTE: Exceeding these values may cause serious damage to the control board. These are fault rating not normal operating conditions.

NOTE: Note that the maximum ratings shown below are an indication of the input’s ability to withstand being incorrectly connected to an external voltage source. In normal operation NO voltage should be connected to the control board’s inputs. Although the inputs will not be damaged by an input voltage less than or equal to the maximum rating it is not implied that the control board will function correctly while that input is under such a condition.

Written Instructions:

How to Program the ATA CB6 Control Board

Video Instructions:

Coming Soon

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Features:

  • 1 x Genuine ATA CB6 Control Board
  • Controls up to 2 AC motors (either single or three phase – via contactors) with microprocessor logic
  • 2 Years Manufacturer’s Warranty*
  • Free Standard Shipping Australia-Wide*

Includes:

  • 1 x ATA CB6 Control Board
  • Weather resistant control box
  • 240V transformer
  • Installation Instructions

Note:  Receiver or transmitters or inverter are NOT included in this product.

Compatibility List:

The CB6 Control Board is compatible with ATA Industrial Gate and Shutters.

Control up to two AC motors (either single or three phase – via contactors) with microprocessor logic. The CB6 Control Board offers true flexibility with a variety of input triggers including Safety Beam, swipe card, loop detector, etc.

 

Weight.5 kg
Application

, ,

Brand

ATA

Type

 MinimumMaximum
Supply Voltage240 VAC Supply450V peak
24 VAC Supply29VAC
Input VoltagesControl and Safety Inputs-50 Volts100 Volts
Limit Switch Inputs-50 Volts100 Volts
OutputsLock Output (switching voltage)30 VAC / DC
Lock Output (switching current [inductive])3 AMPS
Light Output Module (switching voltage)240 VAC / 30 VDC
Light Output Module (switching current)10A AC / DC
Total Motor Output Current5 AMP (5 AMP fuse protected)

 

NOTE: Exceeding these values may cause serious damage to the control board. These are fault rating not normal operating conditions.

NOTE: Note that the maximum ratings shown below are an indication of the input’s ability to withstand being incorrectly connected to an external voltage source. In normal operation NO voltage should be connected to the control board’s inputs. Although the inputs will not be damaged by an input voltage less than or equal to the maximum rating it is not implied that the control board will function correctly while that input is under such a condition.